Study of Rapid Visual Screening of Buildings for High Potential Seismic Hazard According to Indonesian Standard

Endah Wahyuni, Pujo Aji, Firman Budi

Abstract


This paper presents a study of Rapid Visual Screening (RVS) using FEMA 154 and applied in Indonesia based on SNI 1726. RVS is a method to asses potential earthquake hazard of a building based on visual observation (“sidewalk survey”) of the exterior and interior building if possible, and a Data Collection Form. This study is intended to see how important the RVS of the FEMA 154 can be implemented in Indonesia with a case study at Yogyakarta. The buildings that reviewed were assumed to have the same parameters as mention in FEMA 154 and compatible with SNI 1726 (Indonesian earthquake map). The results from field survey were compared to the numerical analysis. From the case study, it was found that the administration building of ATK Academy, the dormitory building of Ministry of Internal Affairs, the office building of Department of Agriculture, and the educational building of Health Polytechnics have a score more than 2, and the buildings are also declared safe according to SNI 1726.


Keywords


Rapid Visual Screening; FEMA 154; High Seismicity; Earthquake

Full Text:

PDF

References


ATC, 2002, Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook (2nd edition), prepared by the Applied Technology Council for the Federal Emergency Management Agency, FEMA 154 Report, Washington D.C.

Badan Standardisasi Nasional, 2012, "Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur bangunan Gedung dan Non Gedung", SNI 1726, Jakarta.

Alfia, F., Aji, P and Wahyuni, E, 2014, "Studi Literatur Rapid Visual Screening untuk Mengetahui Potensi Kerentanan Bangunan Terhadap Bahaya Gempa". Jurnal Teknik POMITS volume 1, Number 1.(2014)1-6.

ASCE, 1998, Handbook for the Seismic Evaluation of Buildings - A Pre-standard, prepared by the American Society of Civil Engineers for the Federal Emergency Management Agency, FEMA 310 Report, Washington D.C.

Wahyuni, E and Tethool, Y, 2015, "Effect of vierendeel panel width and vertical truss spacing ratio in staggered truss framing system under earthquake loads". International Journal of Civil Engineering, Volume 13, Number 2, p. 213-221.