Performance of Split Air Conditioner with Capillary Pipe Variations with R32 Refrigerant on Ships

urip prayogi, Frengki M Felayti, M. Ilham Bintang H

Abstract


The hot temperature on the ship will interfere with the comfort of the crew, so an air conditioning machine is needed to cool down. Hot conditions make air conditioning needed on the ship as a means of cooling when the ship sails. Split AC performance is very necessary so that the temperature released remains optimal. Split air conditioners have many components, for example, capillary pipes, capillary pipes play a very important role in obtaining low temperatures. Therefore, it is necessary to research variations in the length and diameter of capillary pipes. As a pressure-lowering device and regulating the amount of refrigerant liquid flowing, the length and diameter of capillary pipes greatly affect the cooling process. If you find the right and right variation, you will get a temperature lower than the standard Therefore, to get extra cooling for split air conditioners, research is proposed on the effect of variations in the length of capillary pipes on the work performance of split air conditioner machines using R32 refrigerant for ship accommodation room. To know the effect of cooling more extra because with changes in capillary pipes further maximize cold temperatures by using additional capillary pipe length. This study uses an experimental method with a split air conditioner 0.5 Hp as the main object and variations in capillary pipe length. the temperature after the capillary pipe is varied is lower than the standard, namely the standard achievement of 55.9 for a variation of 72 cm, which is 26.4, and the last variation of 159 cm, which is 29.

Keywords


COP, refrigeration effect, freon pressure

Full Text:

PDF

References


Ahmad Imam Rifa'i, Novarini. 2020. “Influence Pressure Refrigerant R-134a To Mark Coefficient of Performance (COP)". Journal Innovator. Vol. 4, No. 2. 9–12.

Poernomo, Heroe. 2015. "Analysis of the Performance Characteristics of a Cooling System (Air Conditioning) Using Freon R-22 Based on Condenser Cooling Fan Rotation Variations." Ships: Journal of Marine Science and Technology 12(1): 1–8.

lukito, Agus, and Ekadewi Anggraini Handoyo. 2002. "Analysis of the Effect of Capillary Tubes Wound in Suction Lines on the Performance of Cooling Machines." Journal of Mechanical Engineering 4(2): 94–98.

Irsyad, Saiful Maulida, and Ary Bachtiar Krishna Putra. 2018. "Experimental Study of the Performance of a Single State Refrigeration System with Varying Expansion Devices." ITS Engineering Journal 7(1): B112–16.

Aziz, Azridjal. 2013. "Comparison of Thermostatic Expansion Valves and Capillary Pipes on Temperature and Pressure of Cooling Machines." In National Seminar on Chemical Engineering, Oleo Technology and Petrochemicals (SNTK TOPI), Pekanbaru ,.

Ardita, I Nengah, IGAB Wirajati, and IDM Susila. 2020. "Analysis Of The Influence Of Connecting Pipe Isolation Damage On The Performance Of Split Ac." In Proceedings of the National Seminar on Applied Innovative Research (SENTRINOV) , , 170–77.

Dwinanda, Dendi. 2003. "Analysis of the Influence of the Shape of the Capillary Tube Bend in the Refrigerator." Gunadarma University .

Tito Adi Nugroho , Kiryanto, Berlian Experimental Study of the Use of Fish Cooling Media in the Form of Wet Ice and Ice Pack as an Effort to Improve the Performance of Fish Storage Places Caught by Fishermen Journal of Marine Engineering - Vol. 4, no. October 4, 2016

Choirudin, Muchammad Fazrul, And Urip Prayogi. 2019. "Technical Analysis Of Fish Hatch Space Cooling System Planning In Km. Pure Mas Star From Refrigerant R-22 (Hcfc-22) To R 134a." Proceedings Of The Seminacles: 36–57

Habli, M Hasan, Pande I Siregar, and Fikri Gigih Harahap. 2021. "Analysis of deterioration occurring in the accommodation space cooling engine that can cause temperature changes on board MT. Prima Lautan I." In Proceedings of the Seminar on Shipping and Applied Technology, , 61–75.

Loegimin, Maruto Swatara et al. 2020. “Sistem Pendinginan Air Untuk Panel Surya Dengan Metode Fuzzy Logic.” Jurnal Integrasi 12(1): 21–30

Kusuma, D D H. 2015. “Pengaruh Variasi Panjang Pipa Kapiler Yang Dililitkanpada Suction Terhdap Prestasi Mesin Pendingin Dengan LPG Sebagai Refrigerant.”

Maulana, Aji. 2019. “Pengaruh Jumlah Lilitan Pipa Kapiler Terhadap Coeficient Of Performance (Cop) Sistem Pendingin Ac Mobil.”

Prayogi, Urip. "Comparative analysis of Global Warming Potential (GWP) and Ozone Depletion Potential (ODP), in refrigerants R32, R290, R407C, R410A, as a substitute for R22." Journal of Mechanical Engineering Mercu Buana 11(1): 14–20




DOI: http://dx.doi.org/10.12962/j25481479.v9i1.20141

Refbacks

  • There are currently no refbacks.


Abstracted / Indexed by:
      
  

 

 

 

 

 

P-ISSN: 2541-5972   

E-ISSN: 2548-1479

 

Lisensi Creative Commons

IJMEIR journal published by  Department of Marine Engineering, Faculty of Marine Technology, Institut Teknologi Sepuluh Nopember Surabaya Indonesia under licenced Creative Commons Attribution-ShareAlike 4.0 International Licence. Based on https://iptek.its.ac.id/index.php/ijmeir/