Evaluation and Analysis of Uncertainty Measurement of The Sound Level Meter Calibration by Coupler Method

Bondan Dwisetyo, Denny Hermawanto

Abstract


The evaluation and analysis of uncertainty measurement of sound level meter calibration by coupler method was carried out by Research Group for Acoustics and Vibration – National Standardization Agency of Indonesia (BSN). The aims of this work is to evaluate and analyze the uncertainty measurement of sound level meter (SLM) calibration using the coupler method, where it is focused for A-frequency weighting as main parameter based on Guide to the expressions of Uncertainty in Measurement (GUM). The uncertainty budgets that obtained of this work consists of a repeated measurement of sound level meter test using the multifunction acoustic calibrator as the reference instrument, readability of SLM, sound pressure level calibration of the reference along with drift of the standard, sound pressure response, the level of accuracy, the total harmonic distortion with noise, and the capability of the used insulation box to insulate background noise from outside. From the result of case study, the standard instrument withal its sound pressure response and level of accuracy has the highest contribution to provide the significant evaluation of the expanded uncertainty at the frequency of 8000 Hz that put of the values are 0,17 dB and 0,14 dB respectively. After that, the obtained expanded uncertainty reach up to 0,48 dB of this frequency. In addition, this result also state that the proposed expanded uncertainty values are below to the maximum of acceptance values that required by IEC 61672-1:2013. Thus, it is acceptable and is considered to be applicated further for the calibration of sound level meter, and other the utilized microphone instruments.

Keywords


uncertainty measurement, GUM, calibration of sound level meter, coupler method

Full Text:

PDF

References


E. Frederiksen, “Acoustic metrology – an overview of calibration methods,” vol. 107, pp. 97–107, 2013.

G. Goulamhoussen and R. Wright, “Sound level meter directional response measurement in a simulated free-field To cite this version : HAL Id : hal-00811207 Sound level meter directional response measurement in a simulated free-field,” 2012.

I.MA.2.06, “Calibration Procedure for Sound Level Meter by Using Multi Frequency Acoustic Calibrator,” 2015.

JCGM, “Evaluation of measurement data — Guide to the expression of uncertainty in measurement,” no. September, 2008.

V. R. Meyer, “Measurement uncertainty,” vol. 1158, pp. 15–24, 2007.

I.MA.2.06.U-E.2-R.0, “Evaluasi Ketidakpastian Kalibrasi Sound Level Meter Menggunakan Multifunction Acoustic Calibrator,” 2019.

IEC 61672-1, Electroacoustics-Sound Level Meters-Part 1: Spesification. International Electroacoustics Commision, 2013.




DOI: http://dx.doi.org/10.12962%2Fj24604682.v17i1.6874

Refbacks

  • There are currently no refbacks.


kadal4d

emon88

slot deposit pulsa

Spotbet

totocxzsvd

https://www.9wavesphilippines.com/

abcslot

bandar togel

https://vescoa.ves.ac.in/courses/

slot88

Omutogel Daftar

Omutogel

slot

Omutogel Situs

Mulantogel

Mulantogel Link

Slot 777

Saldowd

ahok4d

ahok4d

selalubet

poltartoto

selalubet

poltartoto

spvtoto

link slot

slot gacor

https://outreachsocialmedia.com/

Scatter Hitam

https://ijpls.org/

Slot88

Slot88

https://sipp.pa-cirebon.go.id/

Scatter Hitam

https://dtap.undip.ac.id/

sbobet88

https://koperasi-yamaha.com

Asia200

Asia300

matahari88

viral99

matahari88

matahari88

toto 4d

toto 4d

OMUTOGEL

MULANTOGEL

KEITOGEL

JUTACUAN99

Matahari88

เว็บสล็อตเว็บตรง

spvtoto

halutoto

sistoto

poltartoto

arisantoto

tariantoto

selalubet

ahok4d

selalubet

slot gacor

rosohoki

bola slot

situs resmi