Sliding Mode Control System of Single Phase Buck-Boost Inverter with Buffer Inductor

Purwadi Agus Darwito, Arief Abdurrakhman, Almas Fachrullah

Abstract


Inverter is one of the primary components of a distributed electric power plants that serve as modifiers DC voltage into AC. In this research is applied of the Sliding Mode Control on Inverter Buck Boost One phase with Buffer Inductor. In the Open Loop test with the source voltage of 60 Volts, generate graphics output voltage in the form of a sinusoidal wave with maximum amplitude of about 400 volts. In the Closed Loop test, the graph output voltage can be controlled to follow a set point with SMC control method of order 2, and the resulting value Error Steady State smallest at 300 Volt, which amounted to 3.33%. The smallest sensitivity value of 0.29 when the input voltage changes by 32%.

Keywords


Inverter, SPBBI-BI, sliding mode control.

Full Text:

PDF

References


Darwito, Purwadi Agus, Soebagio and Purnomo, Mauridy Heri. A New Topology Of Three Phase Buck-Boost Inverter With Buffer Inductor. Institut Teknologi Sepuluh Nopember, Surabaya : JATIT &LLS, 2013, Vol. 51.

Koushki B., Khalilinia H., Ghaisari J., Saghaian N.M. A New Three-Phase Boost Inverter : Topology And Controller, CCECE/CCGEI May 5-7 2008 Niagara Falls, Canada, 2008.

Shittesel, Y. Sliding Mode Control and Observation. New York : Springer Science+Bussines, 2013.

Tan, Siew-Chong, Lai, Yuk Ming and Tse, Chi Kong. Sliding Mode Control of Switching Power Converters. s.l. : CRC Press, 2012.

Wicaksono, Handy. Analisa Performansi dan Robustness ,Beberapa Metode Tuning Kontroler PID pada Motor DC. Fakultas Teknologi Industri, Jurusan Teknik Elektro, Universitas Kristen Petra. Jurnal Teknik Elektro Vol. 4, No. 2, September 2004: 70 – 78




DOI: http://dx.doi.org/10.12962/j23546026.y2015i1.1107