Sensitive Magnetic Field Sensor Based on Compensated Double Pick Up Coil

Budi Purnama, Suharyana Suharyana, Artono Dwijo Sutomo

Abstract


Sensitive magnetic field sensor based on compensated double pick up coil has been developed. In order to confirm sensitifity of modified design, experiment carried out in two steps. Firstly, sensitify of conventional design is clarified. Here pick up coil as an active sensor and solenoid as an exitation coil is separately made. Secondly, modified sensor of integrated configuration is developed. Here for both active flux gate sensor and the exitation coil is made in same one core magnetic. Ferrite and standar foil soft magnetic is utilized in this experiment. In attention, frequency of 50 Hz is used for the whole experimens. A result showed that sensitvity of the integrated configuration sensor is much larger than conventional one. Then, power consume of the integrated flux gate sensor is much lower than conventional. Finally, a range measurement of the integrated configuration sensor can be realized less than 20 T which potential may perhaps sense a change of natural local magnetic field.

Keywords


double pick up coil; hysteresis curve; magnetic field

Full Text:

PDF

References


P. Ripka, Advance in Fluxgate Sensors, Sensors and Actuators A, no. 106 p.8-14. 2003.

L. Perez, C. Aroca, P. Sanches, E. Lopez and M.C. Sanches, Planar Fluxgate Sensor With An Electrodeposited Amourphous Core, Sensors and Actuator A. no.109. p. 208-211. 2004.

T. O’Donnell, A.Tipek, A.Connell, P. McCloskey, and S. C. O’Mathuna. Planar Fluxgate Current Sensor Integrated In Printed Circuit Board, Sensors and Actuator A no. 129. p. 20-24. 2006.

W.-Y. Choi, K.-Y. Park, B.-C. Koh, M.-S. Kang, K.-W. Na and S.-O. Choi. “A Fabricating Method For A Fluxgate Sensor Integrated In Printed Circuit Board”, U.S. Paten 0172480, A1, 2005.

M. Janosek and P. Ripka, Current-Output of PCB Fluxgates, Sensor Letters, vol. 7. p. 1-4. 2009.

J. Kubik, J. Vcelak, T.O’Donnell and P.Mc.Closkey. Triaxial Fluxgate Sensor With Electroplated Core, Sensors and Actuators A 152. p. 139-145. 2009.

P. Ripka, X.P.Li and J. Pan, Multiwire Core Fluxgate, Sensors and Actuators A, 156. p. 265-268. 2009.

Basschirotto, A. Dallago, E. Ferri, M. Malcovati, P. Rossini, A. and G. Venchi, “A 2D Micro-Fluxgate Earth Magnetic Field Measurement Systems With Fully Automated Acquisition Setup”, Measurement Vol. 43. p. 46-53. 2010.




DOI: http://dx.doi.org/10.12962/j20882033.v23i1.16