Ethylene Evaporation Rate Analysis in the Storage Tank and Boil-Off Gas Dispersion: Case Study in PT Lotte Chemical Titan Nusantara

Orchidea Rachmaniah, Khoir Lazuardi, Ajeng Nina Rizky, Rijaalul Mulhim Al-Mauhub, Ibnu Faridsyah, Bagus Cahyadi

Abstract


As a primary raw material at PT Lotte Chemical Titan Nusantara (LCTN), ethylene storage is 12,000 tons in icy conditions (- 103.6 °C and 40-80 mbarg) before processing into polyethylene. Ethylene evaporation is inevitable. Therefore, the proper handled of ethylene needs to be settled. The evaporation rate or Boil-Off Rate (BOR) of ethylene is predicted to be 0.0705-0.0730% vol/day, and the Boil-Off Gas (BOG) is 9.41-9.76 tons per day (at 21-40 °C and a tank liquid level of 15.41 meters, approx. 52.51% volume of tank). The BOR is a predicted value of the percentage of volume evaporated daily. When the liquid level is increased, the BOR rate will also be increased. The size of any leaks dramatically impacts the gas dispersion radius. A leak with a 10 mm size at wind speeds of 5 and 10 km/hr resulted in the radius distance of BOG dispersion being 8.2 and 7.7 m, respectively. When the leak hole is ten times bigger, ca. 100 mm, the radius is eight times wider. Fortunately, gas releases happen well above ground level (15.5 meters), causing the cloud to rise, keeping personnel safe. Too low liquid levels ramp up evaporation, risking shortages, while overfilling increases BOG, raising the chance of spills and safety hazards. Hence, managing these variables is crucial to keep operations smooth and safe.


Keywords


BOG; BOR; Ethylene; Evaporation Rate; Storage Tank

Full Text:

PDF

References


T. Wlodek, Prediction of Boil Off Rate in Liquefied Natural Gas Storage Processes, Poland: AGH University of Science and Technology, 2017.

I. &. C. B. Hamdhan, Determination of Thermal Conductivity of Coarse and Fine Sand Soils., Bali: World Geothermal Congress 2010, 2010.

ASTM, A553/A553M Standard Specification for Pressure Vessel Plates, Alloy Steel, Quenched and Tempered 7, 8, and 9 % Nickel, https://www.astm.org/a0553_a0553m-17e01.html (Diakses pada 24 Agustus 2023), 2022.

M. d. Khan, Energy Saving through Efficient BOG Prediction and Impact of Static Boil-off-Rate in Full Containment-Type LNG Storage Tank. Energies vol.13: 5578. KSV Proset. T.t. AquaPro Spray PUF, https://www.kvkproset.com/ (Diakses pada 24 Agustus 2023), 2022.

P. Institute, Perlite Loose-Fill Masonry Insulation., https://www.govinfo.gov/ (Diakses pada 24 Agustus 2023), 2013.

D. H. J. S. D. V. P. L. Smith, Effective Thermal Conductivity of a Glass Fiberblanket Standard Reference Material, Boulder: National Bureau of Standards, 1981.

N. C. f. B. Information, Pubchem Compound Summary for CID 6325, Ethylene, https://pubchem.ncbi.nlm.nih.gov/compound/Ethylene (Diakses pada 24 Agustus 2023), 2023.

C. Wiratama, Storage Tank, https://www.aeroengineering.co.id/2021/04/storage-tank/ (Diakses pada 23 Agustus 2023), 2021.

D. Syam, Ethylene Supply and BOG System. Cilegon: PT PENI VSL International. Concrete Storage Structure, Switzerland: VSL International Ltd, 1983.

T. Matweb, ASTM A553 Alloy Steel, Grade I., https://www.matweb.com/search/datasheet.aspx?matguid=15c115d9678143ebb6cc22acb32d8eed&ckck=1 (Diakses pada 24 Agustus 2023).

F. glass, FOAMGLAS Insulation Systems. Pittsburgh: Pittsburgh Corning. GPSA. 2004. Engineering Data Book 12th Edition, Oklahoma: Gas Processors Supplier Association, 2009.

Yellow Book, Chapter 4, Methods for The Calculation of Physical Effects, 1996.

D. A. a. J. F. L. Crowl, Chemical Process Safety, Fundamentals with Applications 3rd edition, Boston: Pearson Education, Inc, 2011.

Guidelines for Chemical Process Quantitative Risk Analysis, CCPS, 2nd Edition, 2000.




DOI: http://dx.doi.org/10.12962%2Fj23378557.v11i1.a21725