Performance of Water Pump on Distribution and Transmission Process using Variable Speed Drive

Dwi Oktavianto Wahyu Nugroho, Totok Soehartanto, Tahta Anugrah Wibowo

Abstract


The Pump is the vital component in the transmission of water from one unit to another or the distribution water from booster unit to customer. Water pumping has become ineffective due to incorrect installation of the installed pump not in accordance with the pre-installed piping. Investing in network development in the coming year is sometimes one of the reasons why pumps are installed improperly. Thus, high pressure pumps are sometimes installed at lower pipeline pressure. This condition usually does not only double between the pressure in the pipe and pump. Classically, pump output lines are usually coupled with valves (usually butterfly or rotary valves) to provide conditions that correspond to the pump's datasheet.  Meanwhile, the classical concept will decrease the lifetime of pump, so the Variable Speed Drive (VSD) becomes the solution. TawangSari, SiwalanPanji, and KedungUling units are picture how VSD can fix kind of problem that faced in classical system. Worst energy use and decreased performance in classical system cause by wrong installation and limitation of supply power are solved by adapting frequency produced by VSD as it needed.




Keywords


pump, installation, Variable Speed Drive, energy, performance

Full Text:

PDF

References


M. Zhu, X. Zhang, Y. Zhang and T. Wang, "Study on water hammer prevention in pumping water supply systems by multivalves,” presented at the Int. Conf. on Hybrid Information

Technology, Cheju Island, Korea, 2006.

W. L. Stebbins, "A user's perspective on the application of

adjustable speed drives and microprocessor control for hvac

savings," presented at the IEEE Annual Textile Industry Technical

Conference, Greenville, SC, USA, 1988.

J. Zhijun and H. Yangyang, "Research of pump-selection in

pressure-superposed water supply," presented at the IEEE Int.

Conf. on Intelligent Computing and Intelligent Systems, Xiamen,

China, 2010.

G. Junzhong, Q. Yuansheng, X. Yafen and L. Yang, "Operation

parameters optimization of centrifugal pumps in multi-sources

water injection system," presented at the International Technology

and Innovation Conference Hangzhou, China, 2006.

Grundfoss, "HS 200-150-483 5/1-F-A-BBVP," Grundfoss.

Google, [Online]. Available:

https://www.google.com/maps/place/IPA+Siwalanpanji/@-

4294806,112.7317153,694m/data=!3m2!1e3!4b1!4m8!1m2!2

m1!1sPDAM+siwalanpanji!3m4!1s0x2dd7e6a0ba68ccaf:0x8cf2f

b2!8m2!3d-7.4294859!4d112.733904. [Accessed 11

2020].

Google, [Online]. Available:

https://www.google.com/maps/place/PDAM+Delta+Tirta/@-

4735845,112.6867185,16.33z/data=!4m12!1m6!3m5!1s0x2dd

e14a69371adf:0xec8d5d0f1f59d285!2sPDAM+Delta+Tirta+Ka

bupaten+Sidoarjo!8m2!3d-

4507982!4d112.7132805!3m4!1s0x0:0xa584b65bd7a2666c!8

m2!3d-7.4742126. [Accessed 12 07 2020].

Google, [Online]. Available:

https://www.google.com/maps/place/PT.+Taman+Tirta+Sidoarjo

,+(PDAM+Tawangsari)/@-

3298157,112.705138,13z/data=!4m5!3m4!1s0x0:0xd67f3558e

b6270ad!8m2!3d-7.3528053!4d112.67591. [Accessed 14 07




DOI: http://dx.doi.org/10.12962/j23378557.v6i2.a7248

Refbacks

  • There are currently no refbacks.


Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License. IPTEK The Journal of Engineering published by Pusat Publikasi Ilmiah, Institut Teknologi Sepuluh Nopember

 

Please contact us for order or further information at: email: iptek.joe[at]gmail.com Fax/Telp: 031 5992945. Editorial Office Address: Pusat Riset Building 6th floor, ITS Campus, Sukolilo, Surabaya 60111, Indonesia.