The Effect of Fan Blade Radiator Gas Turbin Generator Angle on Auxiliary Cooling Water System Performance

Erryawan Kusuma, Agus Sigit Pramono

Abstract


Auxiliary Cooling Water System (ACWS) on Gas turbine Blok 1 No 3 Muara Karang has declined its reliability because of 4 fan radiators must be operated due to increasing ambient air temperature and increase inspection interval from 8000 to 32.000 EOH after Upgrade in turbine part. This study aims to optimize Radiator ACWS performance by increasing the cooling fan air mass flow by changing the fan blade angle so it can be operated with 3 fan on and 1 fan standby. This research began with taking data each measurement at 11°, 13°, 15°, 17°, and 19°. Then, it will simulated by software to know the influence of air mass flow addition due to the change of the blade fan angle to the radiator water outlet temperature and to know the input operating parameters when the temperature outlet radiator is 46°C. The results of this study is validation of experimental and numerical data calculations that have errors below 5%. The maximum angle of fan blade can be set until 19°. At 16.7° with operation 3 of 4 fan on, radiator temperature output is 46° and heat disposed is 627.2 kW where this value is the same value as the current condition.

Keywords


Radiator Outlet Temperature , Cooling Fan, Blade Fan Angle Angle

Full Text:

PDF

References


GE Power, “9E Advanced Gas Path A Power LifeMax* Solution.” 2016.

GE Power, “ExtendorTM Combustion System.” GE Power, 2008.

GE Power, “MS 9000 Service Manual Turbin Accessories and Generator, GEK-98786, Volume 1.” GE Power.

S. Bose, “Improve air-cooled heat exchanger performance,” CEP Magazine, pp. 1–7, Jan-2017.

M. J. Izadi and A. Falahat, “Effect of blade angle of attack and hub to tip ratio on mass flow rate in an axial fan at a fixed rotational speed,” in ASME 2008 Fluids Engineering Division Summer Meeting collocated with the Heat Transfer, Energy Sustainability, and 3rd Energy Nanotechnology Conferences Volume 1: Symposia, Parts A and B, 2008, pp. 903–913.

ASIMPTOTE, Cycle-tempo manual reference guide. Heeswijk-Dinther, Netherlands: ASIMPTOTE.

R. D. Bock, “The performance of an axial flow fan in a small scale A-frame test facility.,” 2017. [Online]. Available: https://scholar.sun.ac.za/handle/10019.1/102757.

M. J. Moran and H. N. Saphiro, Fundamentals of Engineering Thermodynamics. Chichester: John Wiley & Sons Inc, 2011.

F. P. Incropera, D. P. DeWitt, T. L. Bergman, and A. S. Lavine, Fundamentals of heat and mass transfer., 6th ed. Danvers (MA): John Wiley & Sons, 2007.




DOI: http://dx.doi.org/10.12962/j23378557.v5i1.a5023

Refbacks

  • There are currently no refbacks.


Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License. IPTEK The Journal of Engineering published by Pusat Publikasi Ilmiah, Institut Teknologi Sepuluh Nopember

 

Please contact us for order or further information at: email: iptek.joe[at]gmail.com Fax/Telp: 031 5992945. Editorial Office Address: Pusat Riset Building 6th floor, ITS Campus, Sukolilo, Surabaya 60111, Indonesia.